Initial commit
This commit is contained in:
25
AK/README.txt
Normal file
25
AK/README.txt
Normal file
@ -0,0 +1,25 @@
|
||||
|
||||
Notice:
|
||||
You have to change some configuration files becaus the because
|
||||
the configuration of network interfaces must not be equal.
|
||||
|
||||
!! Take care, to use the right device names !!
|
||||
Maybe they are called i.e. 'enp0sXX', but you can rename it.
|
||||
See also : README.rename.netdevices
|
||||
|
||||
For the backup gateway host:
|
||||
eth1 --> LAN
|
||||
eth2 --> WAN or ppp0 (DSL device)
|
||||
|
||||
eth0 --> WLAN or second LAN or what ever
|
||||
or
|
||||
br0 --> WLAN or second LAN or what ever
|
||||
|
||||
|
||||
So you have to change the following files
|
||||
dsl-provider.AK: ppp0 comes over eth2
|
||||
interfaces.AK: see above
|
||||
default_isc-dhcp-server.AK
|
||||
ipt-firewall.AK: LAN device (mostly ) = eth1
|
||||
second LAN WLAN or what ever (if present) = eth0
|
||||
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620.zip
Normal file
BIN
AK/bin/IPMICFG_1.27.0_build.170620.zip
Normal file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/DCMICap.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/DCMICap.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/GenEvt.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/GenEvt.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/IPMICFG.exe
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/IPMICFG.exe
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MBType.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MBType.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MRCCode.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MRCCode.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MRCCode2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/MRCCode2.dat
Executable file
Binary file not shown.
96
AK/bin/IPMICFG_1.27.0_build.170620/DOS/Menu.dat
Executable file
96
AK/bin/IPMICFG_1.27.0_build.170620/DOS/Menu.dat
Executable file
@ -0,0 +1,96 @@
|
||||
-m Show IP and MAC.
|
||||
-m IP Set IP (format: ###.###.###.###).
|
||||
-a MAC Set MAC (format: ##:##:##:##:##:##).
|
||||
-k Show Subnet Mask.
|
||||
-k Mask Set Subnet Mask (format: ###.###.###.###).
|
||||
-dhcp Get the DHCP status.
|
||||
-dhcp on Enable the DHCP.
|
||||
-dhcp off Disable the DHCP.
|
||||
-g Show Gateway IP.
|
||||
-g IP Set Gateway IP (format: ###.###.###.###).
|
||||
-r BMC cold reset.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-garp on Enable the Gratuitous ARP.
|
||||
-garp off Disable the Gratuitous ARP.
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-ver Get Firmware revision.
|
||||
-vlan Get VLAN status.
|
||||
-vlan on <vlan tag> Enable the VLAN and set the VLAN tag.
|
||||
If VLANtag is not given it uses previously saved value.
|
||||
-vlan off Disable the VLAN.
|
||||
-selftest Checking and reporting on the basic health of BMC.
|
||||
-raw Send a RAW IPMI request and print response.
|
||||
Format: NetFn Cmd [Data1 ... DataN]
|
||||
-fru info Show FRU inventory area Info.
|
||||
-fru list Show all FRU values.
|
||||
-fru cthelp Show chassis type code.
|
||||
-fru help Show help of FRU Write.
|
||||
-fru <field> Show FRU field value.
|
||||
-fru <field> <value> Write FRU.
|
||||
-fru 1m Update Product-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 1p Update Product-Product Name from DMITable to IPMI FRU.
|
||||
-fru 1s Update Product-S/N from DMITable to IPMI FRU.
|
||||
-fru 2m Update Board-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 2p Update Board-Product Name from DMITable to IPMI FRU.
|
||||
-fru 2s Update Board-S/N from DMITable to IPMI FRU.
|
||||
-fru 3s Update Chassis-S/N from DMITable to IPMI FRU.
|
||||
-fru backup <file> Backup FRU to file <Binary format>.
|
||||
-fru restore <file> Restore FRU from file <Binary format>.
|
||||
-fru tbackup <file> Backup FRU to file <Text format>.
|
||||
-fru trestore <file> Restore FRU from file <Text format>.
|
||||
-fru ver <v1> <v2> Get/Set FRU version. (v1 v2 are BCD format)
|
||||
-sel info Show SEL info.
|
||||
-sel list Show SEL records.
|
||||
-sel del Delete all SEL records.
|
||||
-sel raw Show SEL raw data.
|
||||
-sdr [full] Show SDR records and reading.
|
||||
-sdr del <sdr id> Delete SDR record.
|
||||
-sdr ver <v1> <v2> Get/Set SDR version. (v1 v2 are BCD format)
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo [full] Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge Set auto discharge by days.
|
||||
<module> <day>.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-user list List user privilege information.
|
||||
-user help Show user privilege code.
|
||||
-user add <user id> Add user.
|
||||
<name> <password>
|
||||
<privilege>
|
||||
-user del <user id> Delete user.
|
||||
-user level <user id> Update user privilege.
|
||||
<privilege>
|
||||
-user setpwd Update user password.
|
||||
<user id> <password>
|
||||
-conf upload <file> Upload IPMI configuration form binary file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> Upload IPMI configuration from text file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf tdownload Download IPMI configuration to text file.
|
||||
<file>
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force to boot from
|
||||
device.
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/PMBusStatus.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/PMBusStatus.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt1.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt1.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt2.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt3.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt3.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt4.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt4.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt5.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/SpecEvt5.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/sdc.exe
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/DOS/sdc.exe
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/IPMICFG_UserGuide.pdf
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/IPMICFG_UserGuide.pdf
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/DCMICap.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/DCMICap.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/GenEvt.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/GenEvt.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/IPMICFG-Linux.x86
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/IPMICFG-Linux.x86
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MBType.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MBType.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MRCCode.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MRCCode.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MRCCode2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/MRCCode2.dat
Executable file
Binary file not shown.
96
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/Menu.dat
Executable file
96
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/Menu.dat
Executable file
@ -0,0 +1,96 @@
|
||||
-m Show IP and MAC.
|
||||
-m IP Set IP (format: ###.###.###.###).
|
||||
-a MAC Set MAC (format: ##:##:##:##:##:##).
|
||||
-k Show Subnet Mask.
|
||||
-k Mask Set Subnet Mask (format: ###.###.###.###).
|
||||
-dhcp Get the DHCP status.
|
||||
-dhcp on Enable the DHCP.
|
||||
-dhcp off Disable the DHCP.
|
||||
-g Show Gateway IP.
|
||||
-g IP Set Gateway IP (format: ###.###.###.###).
|
||||
-r BMC cold reset.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-garp on Enable the Gratuitous ARP.
|
||||
-garp off Disable the Gratuitous ARP.
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-ver Get Firmware revision.
|
||||
-vlan Get VLAN status.
|
||||
-vlan on <vlan tag> Enable the VLAN and set the VLAN tag.
|
||||
If VLANtag is not given it uses previously saved value.
|
||||
-vlan off Disable the VLAN.
|
||||
-selftest Checking and reporting on the basic health of BMC.
|
||||
-raw Send a RAW IPMI request and print response.
|
||||
Format: NetFn Cmd [Data1 ... DataN]
|
||||
-fru info Show FRU inventory area Info.
|
||||
-fru list Show all FRU values.
|
||||
-fru cthelp Show chassis type code.
|
||||
-fru help Show help of FRU Write.
|
||||
-fru <field> Show FRU field value.
|
||||
-fru <field> <value> Write FRU.
|
||||
-fru 1m Update Product-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 1p Update Product-Product Name from DMITable to IPMI FRU.
|
||||
-fru 1s Update Product-S/N from DMITable to IPMI FRU.
|
||||
-fru 2m Update Board-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 2p Update Board-Product Name from DMITable to IPMI FRU.
|
||||
-fru 2s Update Board-S/N from DMITable to IPMI FRU.
|
||||
-fru 3s Update Chassis-S/N from DMITable to IPMI FRU.
|
||||
-fru backup <file> Backup FRU to file <Binary format>.
|
||||
-fru restore <file> Restore FRU from file <Binary format>.
|
||||
-fru tbackup <file> Backup FRU to file <Text format>.
|
||||
-fru trestore <file> Restore FRU from file <Text format>.
|
||||
-fru ver <v1> <v2> Get/Set FRU version. (v1 v2 are BCD format)
|
||||
-sel info Show SEL info.
|
||||
-sel list Show SEL records.
|
||||
-sel del Delete all SEL records.
|
||||
-sel raw Show SEL raw data.
|
||||
-sdr [full] Show SDR records and reading.
|
||||
-sdr del <sdr id> Delete SDR record.
|
||||
-sdr ver <v1> <v2> Get/Set SDR version. (v1 v2 are BCD format)
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo [full] Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge Set auto discharge by days.
|
||||
<module> <day>.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-user list List user privilege information.
|
||||
-user help Show user privilege code.
|
||||
-user add <user id> Add user.
|
||||
<name> <password>
|
||||
<privilege>
|
||||
-user del <user id> Delete user.
|
||||
-user level <user id> Update user privilege.
|
||||
<privilege>
|
||||
-user setpwd Update user password.
|
||||
<user id> <password>
|
||||
-conf upload <file> Upload IPMI configuration form binary file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> Upload IPMI configuration from text file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf tdownload Download IPMI configuration to text file.
|
||||
<file>
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force to boot from
|
||||
device.
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/PMBusStatus.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/PMBusStatus.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt1.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt1.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt2.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt3.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt3.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt4.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt4.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt5.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/32bit/SpecEvt5.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/DCMICap.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/DCMICap.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/GenEvt.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/GenEvt.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/IPMICFG-Linux.x86_64
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/IPMICFG-Linux.x86_64
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MBType.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MBType.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MRCCode.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MRCCode.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MRCCode2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/MRCCode2.dat
Executable file
Binary file not shown.
96
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/Menu.dat
Executable file
96
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/Menu.dat
Executable file
@ -0,0 +1,96 @@
|
||||
-m Show IP and MAC.
|
||||
-m IP Set IP (format: ###.###.###.###).
|
||||
-a MAC Set MAC (format: ##:##:##:##:##:##).
|
||||
-k Show Subnet Mask.
|
||||
-k Mask Set Subnet Mask (format: ###.###.###.###).
|
||||
-dhcp Get the DHCP status.
|
||||
-dhcp on Enable the DHCP.
|
||||
-dhcp off Disable the DHCP.
|
||||
-g Show Gateway IP.
|
||||
-g IP Set Gateway IP (format: ###.###.###.###).
|
||||
-r BMC cold reset.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-garp on Enable the Gratuitous ARP.
|
||||
-garp off Disable the Gratuitous ARP.
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-ver Get Firmware revision.
|
||||
-vlan Get VLAN status.
|
||||
-vlan on <vlan tag> Enable the VLAN and set the VLAN tag.
|
||||
If VLANtag is not given it uses previously saved value.
|
||||
-vlan off Disable the VLAN.
|
||||
-selftest Checking and reporting on the basic health of BMC.
|
||||
-raw Send a RAW IPMI request and print response.
|
||||
Format: NetFn Cmd [Data1 ... DataN]
|
||||
-fru info Show FRU inventory area Info.
|
||||
-fru list Show all FRU values.
|
||||
-fru cthelp Show chassis type code.
|
||||
-fru help Show help of FRU Write.
|
||||
-fru <field> Show FRU field value.
|
||||
-fru <field> <value> Write FRU.
|
||||
-fru 1m Update Product-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 1p Update Product-Product Name from DMITable to IPMI FRU.
|
||||
-fru 1s Update Product-S/N from DMITable to IPMI FRU.
|
||||
-fru 2m Update Board-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 2p Update Board-Product Name from DMITable to IPMI FRU.
|
||||
-fru 2s Update Board-S/N from DMITable to IPMI FRU.
|
||||
-fru 3s Update Chassis-S/N from DMITable to IPMI FRU.
|
||||
-fru backup <file> Backup FRU to file <Binary format>.
|
||||
-fru restore <file> Restore FRU from file <Binary format>.
|
||||
-fru tbackup <file> Backup FRU to file <Text format>.
|
||||
-fru trestore <file> Restore FRU from file <Text format>.
|
||||
-fru ver <v1> <v2> Get/Set FRU version. (v1 v2 are BCD format)
|
||||
-sel info Show SEL info.
|
||||
-sel list Show SEL records.
|
||||
-sel del Delete all SEL records.
|
||||
-sel raw Show SEL raw data.
|
||||
-sdr [full] Show SDR records and reading.
|
||||
-sdr del <sdr id> Delete SDR record.
|
||||
-sdr ver <v1> <v2> Get/Set SDR version. (v1 v2 are BCD format)
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo [full] Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge Set auto discharge by days.
|
||||
<module> <day>.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-user list List user privilege information.
|
||||
-user help Show user privilege code.
|
||||
-user add <user id> Add user.
|
||||
<name> <password>
|
||||
<privilege>
|
||||
-user del <user id> Delete user.
|
||||
-user level <user id> Update user privilege.
|
||||
<privilege>
|
||||
-user setpwd Update user password.
|
||||
<user id> <password>
|
||||
-conf upload <file> Upload IPMI configuration form binary file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> Upload IPMI configuration from text file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf tdownload Download IPMI configuration to text file.
|
||||
<file>
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force to boot from
|
||||
device.
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/PMBusStatus.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/PMBusStatus.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt1.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt1.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt2.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt3.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt3.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt4.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt4.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt5.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Linux/64bit/SpecEvt5.dat
Executable file
Binary file not shown.
246
AK/bin/IPMICFG_1.27.0_build.170620/ReleaseNotes.txt
Executable file
246
AK/bin/IPMICFG_1.27.0_build.170620/ReleaseNotes.txt
Executable file
@ -0,0 +1,246 @@
|
||||
-------------------------------------------------------------------------------
|
||||
Supermicro IPMICFG Release Notes
|
||||
Copyright(c) 2017 by Super Micro Computer, Inc. http://supermicro.com/
|
||||
-------------------------------------------------------------------------------
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Introduction
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG is a command line tool that let user set IPMI command through keyboard
|
||||
controller style (KCS) to the device that support Intelligent Platform
|
||||
Management Interface (IPMI) version 2.0 specifications.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Requirements
|
||||
-------------------------------------------------------------------------------
|
||||
- Operating system:
|
||||
* Microsoft DOS 5.0 or later version
|
||||
* Windows Server 2003, 2008, 2012 (32/64bit), 2016
|
||||
- Operating system must be pre-installed Microsoft Visual C++ 2008 SP1
|
||||
Redistributable Package
|
||||
Download Link:
|
||||
http://www.microsoft.com/en-us/download/details.aspx?id=29
|
||||
- Windows 2008 R2 x64 must be pre-installed KB3033929 patch
|
||||
Download Link:
|
||||
https://www.microsoft.com/en-us/download/details.aspx?id=46083
|
||||
Windows 7/8/8.1/10:
|
||||
- Need disabled UAC(User Account Control) or open a command prompt
|
||||
with a run as administrator.
|
||||
- Windows 7 x64 must be pre-installed KB3033929 patch
|
||||
Download Link:
|
||||
https://www.microsoft.com/en-us/download/details.aspx?id=46148
|
||||
* Linux Kernel version 2.6.x or higher.
|
||||
ex: Red Hat Enterprise Linux (RHEL) 6.8 and 7.2,
|
||||
SUSE Linux Enterprise Server (SLES) 11 SP4 and 12 SP1
|
||||
Ubuntu Server 14.04 LTS and 16.04 LTS
|
||||
* Free Disk Space: 200 MB (Linux, Windows)
|
||||
* Available RAM: 64 MB
|
||||
- Hardware:
|
||||
* Baseboard Management Controller (BMC) must support Intelligent Platform
|
||||
Management Interface (IPMI) version 2.0 specifications.
|
||||
- Software:
|
||||
* -tas, -nvme commands must be installed Thin-Agent Service. The TAS
|
||||
minimum required version is 1.4.0.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Installation and Upgrade Instructions
|
||||
-------------------------------------------------------------------------------
|
||||
- DOS
|
||||
Execute IPMICFG.exe
|
||||
- Windows
|
||||
Execute IMPICFG-Win.exe
|
||||
- Linux
|
||||
If your system has installed OpenIPMI driver, you can enabled Linux IPMI
|
||||
driver:
|
||||
# /etc/init.d/ipmi start
|
||||
or
|
||||
# modprobe ipmi_msghandler
|
||||
# modprobe ipmi_devintf
|
||||
# modprobe ipmi_si
|
||||
Then execute IPMICFG-Linux.x86 or IPMICFG-Linux.x86_64
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Third Party Software
|
||||
-------------------------------------------------------------------------------
|
||||
- Phymem
|
||||
Please refer to
|
||||
http://www.codeproject.com/Articles/35378/Access-Physical-Memory-Port-and-PC
|
||||
I-Configuration for more information.
|
||||
- IPMITool
|
||||
Please refer to
|
||||
http://sourceforge.net/projects/ipmitool for more information.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.27.0 build 170620
|
||||
-------------------------------------------------------------------------------
|
||||
1. Add DCMI commands.
|
||||
2. Add MCU ID support for 0xA5, 0xA6, 0xA7 and 0xA8 on IPMICFG with the "tp"
|
||||
command.
|
||||
3. Disabled Microblade "VBAT" sensor all the upper threshold value.
|
||||
4. Fix getting PMBus's detail status has duplicate information.
|
||||
5. Update NM commands to Node Manager 4.0.
|
||||
6. Support ATEN 8U Superblade firmware.
|
||||
7. Update board ID.
|
||||
8. Update KCS driver.
|
||||
9. Modify PMBus Revision info.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.26.0 build 161123
|
||||
-------------------------------------------------------------------------------
|
||||
1. Support MultiNode config ID = 6 and 12.
|
||||
2. Support MultiNode MCU ID = 0xA7.
|
||||
3. Support TAS 1.4.0.
|
||||
4. Update event log description in SEL command.
|
||||
5. Presenting power module full status information in -pminfo command.
|
||||
6. Improve NVME firmware information in "-nvme info" command.
|
||||
7. Support the watchdog sensor in "-sdr" command.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.25.0 build 160823
|
||||
-------------------------------------------------------------------------------
|
||||
1. Support discrete sensor.
|
||||
2. Support NVME 48 nodes.
|
||||
3. Update FRU chassis type.
|
||||
4. Update board id.
|
||||
5. Modify parameter list format.
|
||||
6. Fix FRU fields too many characters lead to FRU wrong issue.
|
||||
7. Add Get/Set host name command.
|
||||
8. Update Windows KCS driver.
|
||||
9. Fix can't boot from UEFI device issue.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.24.2 build 160517
|
||||
-------------------------------------------------------------------------------
|
||||
1. Fix power reading is incorrect with command nm oem power.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.24.1 build 160222
|
||||
-------------------------------------------------------------------------------
|
||||
1. Update Windows KCS driver.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.24.0 build 160105
|
||||
-------------------------------------------------------------------------------
|
||||
1. Add TAS commands. (Not supported DOS)
|
||||
2. Update NVME commands. (Not supported DOS)
|
||||
3. Add summary command.
|
||||
4. Update board id.
|
||||
5. Update MRC Code for SEL.
|
||||
6. Update SEL description.
|
||||
7. Fix MCU Version value wrong issue.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.23.0 build 151106
|
||||
-------------------------------------------------------------------------------
|
||||
1. Support MicroCloud device in tp commands.
|
||||
2. Fix temperature sensor reading can't display negative issue.
|
||||
3. Fix TJmax value wrong issue.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.22.0 build 150814
|
||||
-------------------------------------------------------------------------------
|
||||
1. Update board id.
|
||||
2. Update GUID.
|
||||
3. When impicfg failed, error message will store to stderr variable.
|
||||
4. When input wrong parameter, ipmicfg will print all the parameters
|
||||
explaination and cancel pause screen mechanism. (Not supported DOS)
|
||||
5. When use not root permission account to launch ipmicfg, ipmicfg will show
|
||||
tip message.
|
||||
6. Fix -sdr hang issue at SuperBlade.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
IPMICFG 1.21.0 build 150615
|
||||
-------------------------------------------------------------------------------
|
||||
1. Add BIOS MRC Code for SEL.
|
||||
2. Add support power consumption sensor(SDR record type = 0x0b).
|
||||
3. Add SDR Type 2 to support PS Status Compact SDR.
|
||||
4. Update Fan mode.
|
||||
5. Udpate SEL description and board id.
|
||||
6. Modify FatTwin Right side node ID.
|
||||
7. Modify TwinPro commands.
|
||||
8. Replace KCS driver.
|
||||
9. Update length of PWS Module Number from 12 bytes to 13 bytes.
|
||||
10. Fix memory ECC error description.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Known Issues, Limitations & Restrictions
|
||||
-------------------------------------------------------------------------------
|
||||
1. 'Destination IP address' in the first entry under alerts subsection is
|
||||
volatile as per the IPMI spec. So, this field will not be saved if restored
|
||||
to factory defaults.
|
||||
|
||||
2. Some parameters need IPMI OEM commands support. If not, the execute result
|
||||
will response error message or information. The parameters include:
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge <module> <day> Set auto discharge by days.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-conf upload <file> <option> Upload IPMI configuration form binary file.
|
||||
option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> <option> Upload IPMI configuration from text file.
|
||||
option: -p | Bypass warning message.
|
||||
-conf tdownload <file> Download IPMI configuration to text file.
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force
|
||||
to boot from device.
|
||||
-recoverbiosinfo Get recovery BIOS information.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force
|
||||
to boot from device.
|
||||
-recoverbiosinfo Get recovery BIOS information.
|
||||
-nvme list Display the existing NVME SSD list.
|
||||
-nvme info NVME SSD information.
|
||||
-nvme rescan Rescan all devices by in band.
|
||||
-nvme insert <aoc> <group> <slot> Insert SSD by out of band.
|
||||
-nvme locate <HDD Name> Locate SSD. (in band)
|
||||
-nvme locate <aoc> <group> <slot> Locate SSD. (out of band)
|
||||
-nvme stoplocate <HDD Name> Stop Locate SSD. (in band)
|
||||
-nvme stoplocate <aoc> <group> <slot> Stop Locate SSD. (out of band)
|
||||
-nvme remove <HDD Name> [option] Remove NVME device. (in band)
|
||||
Usage: option 0: Do eject after remove (Default).
|
||||
option 1: Do not eject after remove.
|
||||
-nvme remove <aoc> <group> <slot> Remove NVME device. (out of band)
|
||||
-nvme smartdata [HDD Name] NVME SMART data.
|
||||
-tp info Get MCU Info.
|
||||
-tp info <type> Get MCU Type Info. (type: 1 - 3)
|
||||
-tp nodeid Get Node ID.
|
||||
-tas info Get TAS Information.
|
||||
-tas pause Pause TAS Service.
|
||||
-tas resume Resume TAS Service.
|
||||
-tas refresh Trigger TAS to recollect data.
|
||||
-tas clear Clear TAS collected data in BMC.
|
||||
-tas period <sec> Set TAS update period <limit 5 to 60 sec>.
|
||||
-tas exec <cmd> Execute a user's specified command.
|
||||
|
||||
-------------------------------------------------------------------------------
|
||||
Technical Support
|
||||
-------------------------------------------------------------------------------
|
||||
Web Site: www.supermicro.com
|
||||
Headquarters: support@supermicro.com
|
||||
European Branch: support@supermicro.nl
|
||||
Asian Branch: support@supermicro.com.tw
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/DCMICap.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/DCMICap.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/GenEvt.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/GenEvt.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/IPMICFG-Win.exe
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/IPMICFG-Win.exe
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MBType.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MBType.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MRCCode.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MRCCode.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MRCCode2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/MRCCode2.dat
Executable file
Binary file not shown.
96
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/Menu.dat
Executable file
96
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/Menu.dat
Executable file
@ -0,0 +1,96 @@
|
||||
-m Show IP and MAC.
|
||||
-m IP Set IP (format: ###.###.###.###).
|
||||
-a MAC Set MAC (format: ##:##:##:##:##:##).
|
||||
-k Show Subnet Mask.
|
||||
-k Mask Set Subnet Mask (format: ###.###.###.###).
|
||||
-dhcp Get the DHCP status.
|
||||
-dhcp on Enable the DHCP.
|
||||
-dhcp off Disable the DHCP.
|
||||
-g Show Gateway IP.
|
||||
-g IP Set Gateway IP (format: ###.###.###.###).
|
||||
-r BMC cold reset.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-garp on Enable the Gratuitous ARP.
|
||||
-garp off Disable the Gratuitous ARP.
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-ver Get Firmware revision.
|
||||
-vlan Get VLAN status.
|
||||
-vlan on <vlan tag> Enable the VLAN and set the VLAN tag.
|
||||
If VLANtag is not given it uses previously saved value.
|
||||
-vlan off Disable the VLAN.
|
||||
-selftest Checking and reporting on the basic health of BMC.
|
||||
-raw Send a RAW IPMI request and print response.
|
||||
Format: NetFn Cmd [Data1 ... DataN]
|
||||
-fru info Show FRU inventory area Info.
|
||||
-fru list Show all FRU values.
|
||||
-fru cthelp Show chassis type code.
|
||||
-fru help Show help of FRU Write.
|
||||
-fru <field> Show FRU field value.
|
||||
-fru <field> <value> Write FRU.
|
||||
-fru 1m Update Product-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 1p Update Product-Product Name from DMITable to IPMI FRU.
|
||||
-fru 1s Update Product-S/N from DMITable to IPMI FRU.
|
||||
-fru 2m Update Board-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 2p Update Board-Product Name from DMITable to IPMI FRU.
|
||||
-fru 2s Update Board-S/N from DMITable to IPMI FRU.
|
||||
-fru 3s Update Chassis-S/N from DMITable to IPMI FRU.
|
||||
-fru backup <file> Backup FRU to file <Binary format>.
|
||||
-fru restore <file> Restore FRU from file <Binary format>.
|
||||
-fru tbackup <file> Backup FRU to file <Text format>.
|
||||
-fru trestore <file> Restore FRU from file <Text format>.
|
||||
-fru ver <v1> <v2> Get/Set FRU version. (v1 v2 are BCD format)
|
||||
-sel info Show SEL info.
|
||||
-sel list Show SEL records.
|
||||
-sel del Delete all SEL records.
|
||||
-sel raw Show SEL raw data.
|
||||
-sdr [full] Show SDR records and reading.
|
||||
-sdr del <sdr id> Delete SDR record.
|
||||
-sdr ver <v1> <v2> Get/Set SDR version. (v1 v2 are BCD format)
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo [full] Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge Set auto discharge by days.
|
||||
<module> <day>.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-user list List user privilege information.
|
||||
-user help Show user privilege code.
|
||||
-user add <user id> Add user.
|
||||
<name> <password>
|
||||
<privilege>
|
||||
-user del <user id> Delete user.
|
||||
-user level <user id> Update user privilege.
|
||||
<privilege>
|
||||
-user setpwd Update user password.
|
||||
<user id> <password>
|
||||
-conf upload <file> Upload IPMI configuration form binary file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> Upload IPMI configuration from text file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf tdownload Download IPMI configuration to text file.
|
||||
<file>
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force to boot from
|
||||
device.
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/PMBusStatus.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/PMBusStatus.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt1.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt1.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt2.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt3.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt3.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt4.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt4.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt5.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/SpecEvt5.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/phymem32.sys
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/phymem32.sys
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/pmdll.dll
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/32bit/pmdll.dll
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/DCMICap.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/DCMICap.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/GenEvt.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/GenEvt.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/IPMICFG-Win.exe
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/IPMICFG-Win.exe
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MBType.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MBType.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MRCCode.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MRCCode.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MRCCode2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/MRCCode2.dat
Executable file
Binary file not shown.
96
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/Menu.dat
Executable file
96
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/Menu.dat
Executable file
@ -0,0 +1,96 @@
|
||||
-m Show IP and MAC.
|
||||
-m IP Set IP (format: ###.###.###.###).
|
||||
-a MAC Set MAC (format: ##:##:##:##:##:##).
|
||||
-k Show Subnet Mask.
|
||||
-k Mask Set Subnet Mask (format: ###.###.###.###).
|
||||
-dhcp Get the DHCP status.
|
||||
-dhcp on Enable the DHCP.
|
||||
-dhcp off Disable the DHCP.
|
||||
-g Show Gateway IP.
|
||||
-g IP Set Gateway IP (format: ###.###.###.###).
|
||||
-r BMC cold reset.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-garp on Enable the Gratuitous ARP.
|
||||
-garp off Disable the Gratuitous ARP.
|
||||
-fd Reset to the factory default.
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fdl Reset to the factory default. (Clean LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-fde Reset to the factory default. (Clean FRU & LAN)
|
||||
option: -d | Detected IPMI device for BMC reset.
|
||||
-ver Get Firmware revision.
|
||||
-vlan Get VLAN status.
|
||||
-vlan on <vlan tag> Enable the VLAN and set the VLAN tag.
|
||||
If VLANtag is not given it uses previously saved value.
|
||||
-vlan off Disable the VLAN.
|
||||
-selftest Checking and reporting on the basic health of BMC.
|
||||
-raw Send a RAW IPMI request and print response.
|
||||
Format: NetFn Cmd [Data1 ... DataN]
|
||||
-fru info Show FRU inventory area Info.
|
||||
-fru list Show all FRU values.
|
||||
-fru cthelp Show chassis type code.
|
||||
-fru help Show help of FRU Write.
|
||||
-fru <field> Show FRU field value.
|
||||
-fru <field> <value> Write FRU.
|
||||
-fru 1m Update Product-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 1p Update Product-Product Name from DMITable to IPMI FRU.
|
||||
-fru 1s Update Product-S/N from DMITable to IPMI FRU.
|
||||
-fru 2m Update Board-Manufacturer from DMITable to IPMI FRU.
|
||||
-fru 2p Update Board-Product Name from DMITable to IPMI FRU.
|
||||
-fru 2s Update Board-S/N from DMITable to IPMI FRU.
|
||||
-fru 3s Update Chassis-S/N from DMITable to IPMI FRU.
|
||||
-fru backup <file> Backup FRU to file <Binary format>.
|
||||
-fru restore <file> Restore FRU from file <Binary format>.
|
||||
-fru tbackup <file> Backup FRU to file <Text format>.
|
||||
-fru trestore <file> Restore FRU from file <Text format>.
|
||||
-fru ver <v1> <v2> Get/Set FRU version. (v1 v2 are BCD format)
|
||||
-sel info Show SEL info.
|
||||
-sel list Show SEL records.
|
||||
-sel del Delete all SEL records.
|
||||
-sel raw Show SEL raw data.
|
||||
-sdr [full] Show SDR records and reading.
|
||||
-sdr del <sdr id> Delete SDR record.
|
||||
-sdr ver <v1> <v2> Get/Set SDR version. (v1 v2 are BCD format)
|
||||
-nm nmsdr Display NM SDR.
|
||||
-nm seltime Get SEL time.
|
||||
-nm deviceid Get ME Device ID.
|
||||
-nm reset Reboots ME.
|
||||
-nm reset2default Force ME reset to Default.
|
||||
-nm updatemode Force ME to Update Mode.
|
||||
-nm selftest Get Self Test Results.
|
||||
-nm listimagesinfo List ME Images information.
|
||||
-nm oemgetpower OEM Power command for ME.
|
||||
-nm oemgettemp OEM Temp. command for ME.
|
||||
-nm pstate Get Max allowed CPU P-State.
|
||||
-nm tstate Get Max allowed CPU T-State.
|
||||
-nm cpumemtemp Get CPU/Memory temperature.
|
||||
-nm hostcpudata Get host CPU data.
|
||||
-fan Get Fan Mode.
|
||||
-fan <mode> Set Fan Mode.
|
||||
-pminfo [full] Power supply PMBus health.
|
||||
-psfruinfo Power supply FRU health.
|
||||
-psbbpinfo Battery backup power status.
|
||||
-autodischarge Set auto discharge by days.
|
||||
<module> <day>.
|
||||
-discharge <module> Manually discharge battery.
|
||||
-user list List user privilege information.
|
||||
-user help Show user privilege code.
|
||||
-user add <user id> Add user.
|
||||
<name> <password>
|
||||
<privilege>
|
||||
-user del <user id> Delete user.
|
||||
-user level <user id> Update user privilege.
|
||||
<privilege>
|
||||
-user setpwd Update user password.
|
||||
<user id> <password>
|
||||
-conf upload <file> Upload IPMI configuration form binary file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf download <file> Download IPMI configuration to binary file.
|
||||
-conf tupload <file> Upload IPMI configuration from text file.
|
||||
<option> option: -p | Bypass warning message.
|
||||
-conf tdownload Download IPMI configuration to text file.
|
||||
<file>
|
||||
-clrint Clear chassis intrusion.
|
||||
-reset <index> Reset System and force to boot from device.
|
||||
-soft <index> Initiate a soft-shutdown for OS and force to boot from
|
||||
device.
|
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/PMBusStatus.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/PMBusStatus.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt1.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt1.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt2.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt2.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt3.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt3.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt4.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt4.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt5.dat
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/SpecEvt5.dat
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/phymem64.sys
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/phymem64.sys
Executable file
Binary file not shown.
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/pmdll.dll
Executable file
BIN
AK/bin/IPMICFG_1.27.0_build.170620/Windows/64bit/pmdll.dll
Executable file
Binary file not shown.
1
AK/bin/admin-stuff
Submodule
1
AK/bin/admin-stuff
Submodule
Submodule AK/bin/admin-stuff added at 6c91fc0987
1
AK/bin/manage-gw-config
Submodule
1
AK/bin/manage-gw-config
Submodule
Submodule AK/bin/manage-gw-config added at 2a96dfdc8f
1
AK/bin/monitoring
Submodule
1
AK/bin/monitoring
Submodule
Submodule AK/bin/monitoring added at 0611d0a2ad
1
AK/bin/postfix
Submodule
1
AK/bin/postfix
Submodule
Submodule AK/bin/postfix added at c1934d5bde
69
AK/bind/bind.keys
Normal file
69
AK/bind/bind.keys
Normal file
@ -0,0 +1,69 @@
|
||||
# The bind.keys file is used to override the built-in DNSSEC trust anchors
|
||||
# which are included as part of BIND 9. As of the current release, the only
|
||||
# trust anchors it contains are those for the DNS root zone ("."), and for
|
||||
# the ISC DNSSEC Lookaside Validation zone ("dlv.isc.org"). Trust anchors
|
||||
# for any other zones MUST be configured elsewhere; if they are configured
|
||||
# here, they will not be recognized or used by named.
|
||||
#
|
||||
# The built-in trust anchors are provided for convenience of configuration.
|
||||
# They are not activated within named.conf unless specifically switched on.
|
||||
# To use the built-in root key, set "dnssec-validation auto;" in
|
||||
# named.conf options. To use the built-in DLV key, set
|
||||
# "dnssec-lookaside auto;". Without these options being set,
|
||||
# the keys in this file are ignored.
|
||||
#
|
||||
# This file is NOT expected to be user-configured.
|
||||
#
|
||||
# These keys are current as of Feburary 2017. If any key fails to
|
||||
# initialize correctly, it may have expired. In that event you should
|
||||
# replace this file with a current version. The latest version of
|
||||
# bind.keys can always be obtained from ISC at https://www.isc.org/bind-keys.
|
||||
|
||||
managed-keys {
|
||||
# ISC DLV: See https://www.isc.org/solutions/dlv for details.
|
||||
#
|
||||
# NOTE: The ISC DLV zone is being phased out as of February 2017;
|
||||
# the key will remain in place but the zone will be otherwise empty.
|
||||
# Configuring "dnssec-lookaside auto;" to activate this key is
|
||||
# harmless, but is no longer useful and is not recommended.
|
||||
dlv.isc.org. initial-key 257 3 5 "BEAAAAPHMu/5onzrEE7z1egmhg/WPO0+juoZrW3euWEn4MxDCE1+lLy2
|
||||
brhQv5rN32RKtMzX6Mj70jdzeND4XknW58dnJNPCxn8+jAGl2FZLK8t+
|
||||
1uq4W+nnA3qO2+DL+k6BD4mewMLbIYFwe0PG73Te9fZ2kJb56dhgMde5
|
||||
ymX4BI/oQ+cAK50/xvJv00Frf8kw6ucMTwFlgPe+jnGxPPEmHAte/URk
|
||||
Y62ZfkLoBAADLHQ9IrS2tryAe7mbBZVcOwIeU/Rw/mRx/vwwMCTgNboM
|
||||
QKtUdvNXDrYJDSHZws3xiRXF1Rf+al9UmZfSav/4NWLKjHzpT59k/VSt
|
||||
TDN0YUuWrBNh";
|
||||
|
||||
# ROOT KEYS: See https://data.iana.org/root-anchors/root-anchors.xml
|
||||
# for current trust anchor information.
|
||||
#
|
||||
# These keys are activated by setting "dnssec-validation auto;"
|
||||
# in named.conf.
|
||||
#
|
||||
# This key (19036) is to be phased out starting in 2017. It will
|
||||
# remain in the root zone for some time after its successor key
|
||||
# has been added. It will remain this file until it is removed from
|
||||
# the root zone.
|
||||
. initial-key 257 3 8 "AwEAAagAIKlVZrpC6Ia7gEzahOR+9W29euxhJhVVLOyQbSEW0O8gcCjF
|
||||
FVQUTf6v58fLjwBd0YI0EzrAcQqBGCzh/RStIoO8g0NfnfL2MTJRkxoX
|
||||
bfDaUeVPQuYEhg37NZWAJQ9VnMVDxP/VHL496M/QZxkjf5/Efucp2gaD
|
||||
X6RS6CXpoY68LsvPVjR0ZSwzz1apAzvN9dlzEheX7ICJBBtuA6G3LQpz
|
||||
W5hOA2hzCTMjJPJ8LbqF6dsV6DoBQzgul0sGIcGOYl7OyQdXfZ57relS
|
||||
Qageu+ipAdTTJ25AsRTAoub8ONGcLmqrAmRLKBP1dfwhYB4N7knNnulq
|
||||
QxA+Uk1ihz0=";
|
||||
|
||||
# This key (20326) is to be published in the root zone in 2017.
|
||||
# Servers which were already using the old key (19036) should
|
||||
# roll seamlessly to this new one via RFC 5011 rollover. Servers
|
||||
# being set up for the first time can use the contents of this
|
||||
# file as initializing keys; thereafter, the keys in the
|
||||
# managed key database will be trusted and maintained
|
||||
# automatically.
|
||||
. initial-key 257 3 8 "AwEAAaz/tAm8yTn4Mfeh5eyI96WSVexTBAvkMgJzkKTOiW1vkIbzxeF3
|
||||
+/4RgWOq7HrxRixHlFlExOLAJr5emLvN7SWXgnLh4+B5xQlNVz8Og8kv
|
||||
ArMtNROxVQuCaSnIDdD5LKyWbRd2n9WGe2R8PzgCmr3EgVLrjyBxWezF
|
||||
0jLHwVN8efS3rCj/EWgvIWgb9tarpVUDK/b58Da+sqqls3eNbuv7pr+e
|
||||
oZG+SrDK6nWeL3c6H5Apxz7LjVc1uTIdsIXxuOLYA4/ilBmSVIzuDWfd
|
||||
RUfhHdY6+cn8HFRm+2hM8AnXGXws9555KrUB5qihylGa8subX2Nn6UwN
|
||||
R1AkUTV74bU=";
|
||||
};
|
12
AK/bind/db.0
Normal file
12
AK/bind/db.0
Normal file
@ -0,0 +1,12 @@
|
||||
;
|
||||
; BIND reverse data file for broadcast zone
|
||||
;
|
||||
$TTL 604800
|
||||
@ IN SOA localhost. root.localhost. (
|
||||
1 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
@ IN NS localhost.
|
13
AK/bind/db.127
Normal file
13
AK/bind/db.127
Normal file
@ -0,0 +1,13 @@
|
||||
;
|
||||
; BIND reverse data file for local loopback interface
|
||||
;
|
||||
$TTL 604800
|
||||
@ IN SOA localhost. root.localhost. (
|
||||
1 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
@ IN NS localhost.
|
||||
1.0.0 IN PTR localhost.
|
23
AK/bind/db.172.16.0.0
Normal file
23
AK/bind/db.172.16.0.0
Normal file
@ -0,0 +1,23 @@
|
||||
;
|
||||
; BIND reverse data file for local ak.netz zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.netz. ckubu.oopen.de. (
|
||||
2014121401 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
IN NS ns-ak.ak.netz.
|
||||
|
||||
|
||||
|
||||
; - Fritz! Box Accesspoint
|
||||
1 IN PTR gw-ak.ak.netz.
|
||||
|
||||
|
||||
; - (Caching ) Nameserver
|
||||
254 IN PTR gw-fritz.ak.netz.
|
||||
|
103
AK/bind/db.192.168.0.0
Normal file
103
AK/bind/db.192.168.0.0
Normal file
@ -0,0 +1,103 @@
|
||||
;
|
||||
; BIND reverse data file for local ak.netz zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.netz. ckubu.oopen.de. (
|
||||
2016022601 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
IN NS ns-ak.ak.netz.
|
||||
|
||||
|
||||
|
||||
; - Alter Server
|
||||
1 IN PTR at-1.ak.netz.
|
||||
|
||||
; - Frankiermaschine
|
||||
5 IN PTR at-5.ak.netz.
|
||||
|
||||
; - Fileserver (neu)
|
||||
10 IN PTR at-10.ak.netz.
|
||||
|
||||
; IPMI
|
||||
11 IN PTR ipmi-at-10.ak.netz.
|
||||
12 IN PTR ipmi-at-44.ak.netz.
|
||||
|
||||
; - w2k-Server
|
||||
14 IN PTR at-14.ak.netz.
|
||||
|
||||
15 IN PTR at-15.ak.netz.
|
||||
16 IN PTR at-16.ak.netz.
|
||||
17 IN PTR at-17.ak.netz.
|
||||
18 IN PTR at-18.ak.netz.
|
||||
19 IN PTR at-19.ak.netz.
|
||||
|
||||
; - Renate ALT
|
||||
20 IN PTR at-20.ak.netz.
|
||||
22 IN PTR at-22.ak.netz.
|
||||
|
||||
; - Anke
|
||||
21 IN PTR at-21.ak.netz.
|
||||
|
||||
; - Renate NEU
|
||||
22 IN PTR at-22.ak.netz.
|
||||
|
||||
; - fibu
|
||||
23 IN PTR at-23.ak.netz.
|
||||
|
||||
24 IN PTR at-24.ak.netz.
|
||||
25 IN PTR at-25.ak.netz.
|
||||
|
||||
; - Redaktion/Technik
|
||||
26 IN PTR at-26.ak.netz.
|
||||
27 IN PTR at-27.ak.netz.
|
||||
28 IN PTR at-28.ak.netz.
|
||||
|
||||
30 IN PTR at-30.ak.netz.
|
||||
31 IN PTR at-31.ak.netz.
|
||||
32 IN PTR at-32.ak.netz.
|
||||
|
||||
40 IN PTR at-40.ak.netz.
|
||||
41 IN PTR at-41.ak.netz.
|
||||
|
||||
; - Neuer server
|
||||
;44 IN PTR at-44.ak.netz.
|
||||
44 IN PTR at-44.ak.netz.
|
||||
|
||||
; - Server LAN 2
|
||||
45 IN PTR at-45.ak.netz.
|
||||
|
||||
; - VPN, CMS Backup
|
||||
48 IN PTR at-48.ak.netz.
|
||||
|
||||
; - Hans Hermann (Vertrieb)
|
||||
49 IN PTR at-49.ak.netz.
|
||||
|
||||
; - Redaktionsrechner (einer von 4) Jens
|
||||
50 IN PTR at-50.ak.netz.
|
||||
|
||||
; - dialin-adresse
|
||||
100 IN PTR at-100.ak.netz.
|
||||
|
||||
; - reserviert fuer Notebook Martin
|
||||
101 IN PTR at-101.ak.netz.
|
||||
|
||||
; - lancom-1
|
||||
102 IN PTR at-102.ak.netz.
|
||||
|
||||
; - nas
|
||||
103 IN PTR at-103.ak.netz.
|
||||
|
||||
; - Drucker
|
||||
249 IN PTR hp-lj5000.ak.netz.
|
||||
252 IN PTR canon-ir.ak.netz.
|
||||
253 IN PTR canon-c5030i.ak.netz.
|
||||
|
||||
|
||||
; - (Caching ) Nameserver
|
||||
254 IN PTR ns-ak.ak.netz.
|
||||
|
23
AK/bind/db.192.168.128.0
Normal file
23
AK/bind/db.192.168.128.0
Normal file
@ -0,0 +1,23 @@
|
||||
;
|
||||
; BIND reverse data file for local ak.netz zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.netz. ckubu.oopen.de. (
|
||||
2014121401 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
IN NS ns-ak.ak.netz.
|
||||
|
||||
|
||||
|
||||
; - Fritz! Box Accesspoint
|
||||
103 IN PTR ap-fritz.ak.netz.
|
||||
|
||||
|
||||
; - (Caching ) Nameserver
|
||||
254 IN PTR ns-ak.ak.netz.
|
||||
|
12
AK/bind/db.255
Normal file
12
AK/bind/db.255
Normal file
@ -0,0 +1,12 @@
|
||||
;
|
||||
; BIND reverse data file for broadcast zone
|
||||
;
|
||||
$TTL 604800
|
||||
@ IN SOA localhost. root.localhost. (
|
||||
1 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
@ IN NS localhost.
|
135
AK/bind/db.ak.local
Normal file
135
AK/bind/db.ak.local
Normal file
@ -0,0 +1,135 @@
|
||||
;
|
||||
; BIND data file for local ak.local zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.local. ckubu.oopen.de. (
|
||||
2016051601 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
|
||||
IN NS ns-ak.ak.local.
|
||||
|
||||
; - Alter Server
|
||||
at-1 IN A 192.168.0.1
|
||||
|
||||
; - Frankiermaschine
|
||||
at-5 IN A 192.168.0.5
|
||||
|
||||
; - Fileserver (neu)
|
||||
at-10 IN A 192.168.0.10
|
||||
at-server IN CNAME at-10
|
||||
ldap IN CNAME at-10
|
||||
git IN CNAME at-10
|
||||
web IN CNAME at-10
|
||||
wiki IN CNAME at-10
|
||||
|
||||
; IPMI
|
||||
ipmi-at-10 IN A 192.168.0.11
|
||||
ipmi-at-44 IN A 192.168.0.12
|
||||
ipmi IN CNAME ipmi-at-44
|
||||
|
||||
; - w2k-Server
|
||||
at-14 IN A 192.168.0.14
|
||||
wsus IN CNAME at-14
|
||||
|
||||
at-15 IN A 192.168.0.15
|
||||
at-16 IN A 192.168.0.16
|
||||
at-17 IN A 192.168.0.17
|
||||
at-18 IN A 192.168.0.18
|
||||
at-19 IN A 192.168.0.19
|
||||
|
||||
; - Renate ALT
|
||||
at-20 IN A 192.168.0.20
|
||||
at-22 IN A 192.168.0.22
|
||||
renate IN CNAME at-22
|
||||
; - Anke
|
||||
at-21 IN A 192.168.0.21
|
||||
anke IN CNAME at-21
|
||||
; - Renate NEU
|
||||
at-22 IN A 192.168.0.22
|
||||
|
||||
; - fibu
|
||||
at-23 IN A 192.168.0.23
|
||||
fibu IN CNAME at-23
|
||||
|
||||
at-24 IN A 192.168.0.24
|
||||
at-25 IN A 192.168.0.25
|
||||
|
||||
; - Redaktion/Technik
|
||||
at-26 IN A 192.168.0.26
|
||||
at-27 IN A 192.168.0.27
|
||||
at-28 IN A 192.168.0.28
|
||||
|
||||
at-30 IN A 192.168.0.30
|
||||
at-31 IN A 192.168.0.31
|
||||
at-32 IN A 192.168.0.32
|
||||
|
||||
at-40 IN A 192.168.0.40
|
||||
at-41 IN A 192.168.0.41
|
||||
|
||||
; - Vertrieb
|
||||
at-42 IN A 192.168.0.42
|
||||
at-43 IN A 192.168.0.43
|
||||
|
||||
; - Neuer server
|
||||
;at-44 IN A 192.168.0.44
|
||||
at-44 IN A 192.168.0.44
|
||||
imap IN CNAME at-44
|
||||
smtp IN CNAME at-44
|
||||
|
||||
; - Server LAN 2
|
||||
at-45 IN A 192.168.0.45
|
||||
|
||||
; - VPN, CMS Backup
|
||||
at-48 IN A 192.168.0.48
|
||||
|
||||
; - Hans Hermann (Vertrieb)
|
||||
at-49 IN A 192.168.0.49
|
||||
|
||||
; - Redaktionsrechner (einer von 4) Jens
|
||||
at-50 IN A 192.168.0.50
|
||||
at-51 IN A 192.168.0.51
|
||||
at-52 IN A 192.168.0.52
|
||||
|
||||
; - dialin-adresse
|
||||
at-100 IN A 192.168.0.100
|
||||
|
||||
; - reserviert fuer Notebook Martin
|
||||
at-101 IN A 192.168.0.101
|
||||
|
||||
; - lancom-1
|
||||
lancom-1 IN A 192.168.0.102
|
||||
|
||||
; - nas
|
||||
nas-1 IN A 192.168.0.103
|
||||
|
||||
; - Drucker
|
||||
hp-lj5000 IN A 192.168.0.249
|
||||
canon-ir IN A 192.168.0.252
|
||||
canon-c5030i IN A 192.168.0.253
|
||||
|
||||
; (Caching ) Nameserver
|
||||
ns-ak IN A 192.168.0.254
|
||||
ns IN CNAME ns-ak
|
||||
nscache IN CNAME ns-ak
|
||||
resolver IN CNAME ns-ak
|
||||
at-254 IN CNAME ns-ak
|
||||
|
||||
|
||||
; - 192.168.128.0/24
|
||||
|
||||
ap-fritz IN A 192.168.128.103
|
||||
accesspoint IN CNAME ap-fritz
|
||||
|
||||
|
||||
; - 172.16.0.0/24
|
||||
|
||||
; - Fritz! Box 7390
|
||||
gw-fritz IN A 172.16.0.254
|
||||
fritz.box IN CNAME gw-fritz
|
||||
|
||||
gw-ak IN A 172.16.0.1
|
136
AK/bind/db.ak.netz
Normal file
136
AK/bind/db.ak.netz
Normal file
@ -0,0 +1,136 @@
|
||||
;
|
||||
; BIND data file for local ak.netz zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.netz. ckubu.oopen.de. (
|
||||
2016051601 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
|
||||
IN NS ns-ak.ak.netz.
|
||||
|
||||
; - Alter Server
|
||||
at-1 IN A 192.168.0.1
|
||||
|
||||
; - Frankiermaschine
|
||||
at-5 IN A 192.168.0.5
|
||||
|
||||
; - Fileserver (neu)
|
||||
at-10 IN A 192.168.0.10
|
||||
at-server IN CNAME at-10
|
||||
ldap IN CNAME at-10
|
||||
git IN CNAME at-10
|
||||
web IN CNAME at-10
|
||||
wiki IN CNAME at-10
|
||||
|
||||
; IPMI
|
||||
ipmi-at-10 IN A 192.168.0.11
|
||||
ipmi-at-44 IN A 192.168.0.12
|
||||
ipmi IN CNAME ipmi-at-44
|
||||
|
||||
; - w2k-Server
|
||||
at-14 IN A 192.168.0.14
|
||||
wsus IN CNAME at-14
|
||||
|
||||
at-15 IN A 192.168.0.15
|
||||
at-16 IN A 192.168.0.16
|
||||
at-17 IN A 192.168.0.17
|
||||
at-18 IN A 192.168.0.18
|
||||
at-19 IN A 192.168.0.19
|
||||
|
||||
; - Renate ALT
|
||||
at-20 IN A 192.168.0.20
|
||||
at-22 IN A 192.168.0.22
|
||||
renate IN CNAME at-22
|
||||
|
||||
; - Anke
|
||||
at-21 IN A 192.168.0.21
|
||||
anke IN CNAME at-21
|
||||
; - Renate NEU
|
||||
at-22 IN A 192.168.0.22
|
||||
|
||||
; - fibu
|
||||
at-23 IN A 192.168.0.23
|
||||
fibu IN CNAME at-23
|
||||
|
||||
at-24 IN A 192.168.0.24
|
||||
at-25 IN A 192.168.0.25
|
||||
|
||||
; - Redaktion/Technik
|
||||
at-26 IN A 192.168.0.26
|
||||
at-27 IN A 192.168.0.27
|
||||
at-28 IN A 192.168.0.28
|
||||
|
||||
at-30 IN A 192.168.0.30
|
||||
at-31 IN A 192.168.0.31
|
||||
at-32 IN A 192.168.0.32
|
||||
|
||||
at-40 IN A 192.168.0.40
|
||||
at-41 IN A 192.168.0.41
|
||||
|
||||
; - Vertrieb
|
||||
at-42 IN A 192.168.0.42
|
||||
at-43 IN A 192.168.0.43
|
||||
|
||||
; - Neuer server
|
||||
;at-44 IN A 192.168.0.44
|
||||
at-44 IN A 192.168.0.44
|
||||
imap IN CNAME at-44
|
||||
smtp IN CNAME at-44
|
||||
|
||||
; - Server LAN 2
|
||||
at-45 IN A 192.168.0.45
|
||||
|
||||
; - VPN, CMS Backup
|
||||
at-48 IN A 192.168.0.48
|
||||
|
||||
; - Hans Hermann (Vertrieb)
|
||||
at-49 IN A 192.168.0.49
|
||||
|
||||
; - Redaktionsrechner (einer von 4) Jens
|
||||
at-50 IN A 192.168.0.50
|
||||
at-51 IN A 192.168.0.51
|
||||
at-52 IN A 192.168.0.52
|
||||
|
||||
; - dialin-adresse
|
||||
at-100 IN A 192.168.0.100
|
||||
|
||||
; - reserviert fuer Notebook Martin
|
||||
at-101 IN A 192.168.0.101
|
||||
|
||||
; - lancom-1
|
||||
lancom-1 IN A 192.168.0.102
|
||||
|
||||
; - nas
|
||||
nas-1 IN A 192.168.0.103
|
||||
|
||||
; - Drucker
|
||||
hp-lj5000 IN A 192.168.0.249
|
||||
canon-ir IN A 192.168.0.252
|
||||
canon-c5030i IN A 192.168.0.253
|
||||
|
||||
; (Caching ) Nameserver
|
||||
ns-ak IN A 192.168.0.254
|
||||
ns IN CNAME ns-ak
|
||||
nscache IN CNAME ns-ak
|
||||
resolver IN CNAME ns-ak
|
||||
at-254 IN CNAME ns-ak
|
||||
|
||||
|
||||
; - 192.168.128.0/24
|
||||
|
||||
ap-fritz IN A 192.168.128.103
|
||||
accesspoint IN CNAME ap-fritz
|
||||
|
||||
|
||||
; - 172.16.0.0/24
|
||||
|
||||
; - Fritz! Box 7390
|
||||
gw-fritz IN A 172.16.0.254
|
||||
fritz.box IN CNAME gw-fritz
|
||||
|
||||
gw-ak IN A 172.16.0.1
|
14
AK/bind/db.empty
Normal file
14
AK/bind/db.empty
Normal file
@ -0,0 +1,14 @@
|
||||
; BIND reverse data file for empty rfc1918 zone
|
||||
;
|
||||
; DO NOT EDIT THIS FILE - it is used for multiple zones.
|
||||
; Instead, copy it, edit named.conf, and use that copy.
|
||||
;
|
||||
$TTL 86400
|
||||
@ IN SOA localhost. root.localhost. (
|
||||
1 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
86400 ) ; Negative Cache TTL
|
||||
;
|
||||
@ IN NS localhost.
|
17
AK/bind/db.k1371.dyndns.org
Normal file
17
AK/bind/db.k1371.dyndns.org
Normal file
@ -0,0 +1,17 @@
|
||||
;
|
||||
; BIND data file for k1371.dyndns.org zone
|
||||
;
|
||||
$TTL 43600
|
||||
@ IN SOA ns-ak.ak.netz. ckubu.oopen.de. (
|
||||
2016051601 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
|
||||
|
||||
IN NS ns-ak.ak.netz.
|
||||
|
||||
;@ IN A 192.168.0.44
|
||||
@ IN A 192.168.0.10
|
14
AK/bind/db.local
Normal file
14
AK/bind/db.local
Normal file
@ -0,0 +1,14 @@
|
||||
;
|
||||
; BIND data file for local loopback interface
|
||||
;
|
||||
$TTL 604800
|
||||
@ IN SOA localhost. root.localhost. (
|
||||
2 ; Serial
|
||||
604800 ; Refresh
|
||||
86400 ; Retry
|
||||
2419200 ; Expire
|
||||
604800 ) ; Negative Cache TTL
|
||||
;
|
||||
@ IN NS localhost.
|
||||
@ IN A 127.0.0.1
|
||||
@ IN AAAA ::1
|
90
AK/bind/db.root
Normal file
90
AK/bind/db.root
Normal file
@ -0,0 +1,90 @@
|
||||
; This file holds the information on root name servers needed to
|
||||
; initialize cache of Internet domain name servers
|
||||
; (e.g. reference this file in the "cache . <file>"
|
||||
; configuration file of BIND domain name servers).
|
||||
;
|
||||
; This file is made available by InterNIC
|
||||
; under anonymous FTP as
|
||||
; file /domain/named.cache
|
||||
; on server FTP.INTERNIC.NET
|
||||
; -OR- RS.INTERNIC.NET
|
||||
;
|
||||
; last update: February 17, 2016
|
||||
; related version of root zone: 2016021701
|
||||
;
|
||||
; formerly NS.INTERNIC.NET
|
||||
;
|
||||
. 3600000 NS A.ROOT-SERVERS.NET.
|
||||
A.ROOT-SERVERS.NET. 3600000 A 198.41.0.4
|
||||
A.ROOT-SERVERS.NET. 3600000 AAAA 2001:503:ba3e::2:30
|
||||
;
|
||||
; FORMERLY NS1.ISI.EDU
|
||||
;
|
||||
. 3600000 NS B.ROOT-SERVERS.NET.
|
||||
B.ROOT-SERVERS.NET. 3600000 A 192.228.79.201
|
||||
B.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:84::b
|
||||
;
|
||||
; FORMERLY C.PSI.NET
|
||||
;
|
||||
. 3600000 NS C.ROOT-SERVERS.NET.
|
||||
C.ROOT-SERVERS.NET. 3600000 A 192.33.4.12
|
||||
C.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:2::c
|
||||
;
|
||||
; FORMERLY TERP.UMD.EDU
|
||||
;
|
||||
. 3600000 NS D.ROOT-SERVERS.NET.
|
||||
D.ROOT-SERVERS.NET. 3600000 A 199.7.91.13
|
||||
D.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:2d::d
|
||||
;
|
||||
; FORMERLY NS.NASA.GOV
|
||||
;
|
||||
. 3600000 NS E.ROOT-SERVERS.NET.
|
||||
E.ROOT-SERVERS.NET. 3600000 A 192.203.230.10
|
||||
;
|
||||
; FORMERLY NS.ISC.ORG
|
||||
;
|
||||
. 3600000 NS F.ROOT-SERVERS.NET.
|
||||
F.ROOT-SERVERS.NET. 3600000 A 192.5.5.241
|
||||
F.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:2f::f
|
||||
;
|
||||
; FORMERLY NS.NIC.DDN.MIL
|
||||
;
|
||||
. 3600000 NS G.ROOT-SERVERS.NET.
|
||||
G.ROOT-SERVERS.NET. 3600000 A 192.112.36.4
|
||||
;
|
||||
; FORMERLY AOS.ARL.ARMY.MIL
|
||||
;
|
||||
. 3600000 NS H.ROOT-SERVERS.NET.
|
||||
H.ROOT-SERVERS.NET. 3600000 A 198.97.190.53
|
||||
H.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:1::53
|
||||
;
|
||||
; FORMERLY NIC.NORDU.NET
|
||||
;
|
||||
. 3600000 NS I.ROOT-SERVERS.NET.
|
||||
I.ROOT-SERVERS.NET. 3600000 A 192.36.148.17
|
||||
I.ROOT-SERVERS.NET. 3600000 AAAA 2001:7fe::53
|
||||
;
|
||||
; OPERATED BY VERISIGN, INC.
|
||||
;
|
||||
. 3600000 NS J.ROOT-SERVERS.NET.
|
||||
J.ROOT-SERVERS.NET. 3600000 A 192.58.128.30
|
||||
J.ROOT-SERVERS.NET. 3600000 AAAA 2001:503:c27::2:30
|
||||
;
|
||||
; OPERATED BY RIPE NCC
|
||||
;
|
||||
. 3600000 NS K.ROOT-SERVERS.NET.
|
||||
K.ROOT-SERVERS.NET. 3600000 A 193.0.14.129
|
||||
K.ROOT-SERVERS.NET. 3600000 AAAA 2001:7fd::1
|
||||
;
|
||||
; OPERATED BY ICANN
|
||||
;
|
||||
. 3600000 NS L.ROOT-SERVERS.NET.
|
||||
L.ROOT-SERVERS.NET. 3600000 A 199.7.83.42
|
||||
L.ROOT-SERVERS.NET. 3600000 AAAA 2001:500:3::42
|
||||
;
|
||||
; OPERATED BY WIDE
|
||||
;
|
||||
. 3600000 NS M.ROOT-SERVERS.NET.
|
||||
M.ROOT-SERVERS.NET. 3600000 A 202.12.27.33
|
||||
M.ROOT-SERVERS.NET. 3600000 AAAA 2001:dc3::35
|
||||
; End of file
|
11
AK/bind/named.conf
Normal file
11
AK/bind/named.conf
Normal file
@ -0,0 +1,11 @@
|
||||
// This is the primary configuration file for the BIND DNS server named.
|
||||
//
|
||||
// Please read /usr/share/doc/bind9/README.Debian.gz for information on the
|
||||
// structure of BIND configuration files in Debian, *BEFORE* you customize
|
||||
// this configuration file.
|
||||
//
|
||||
// If you are just adding zones, please do that in /etc/bind/named.conf.local
|
||||
|
||||
include "/etc/bind/named.conf.options";
|
||||
include "/etc/bind/named.conf.local";
|
||||
include "/etc/bind/named.conf.default-zones";
|
30
AK/bind/named.conf.default-zones
Normal file
30
AK/bind/named.conf.default-zones
Normal file
@ -0,0 +1,30 @@
|
||||
// prime the server with knowledge of the root servers
|
||||
zone "." {
|
||||
type hint;
|
||||
file "/etc/bind/db.root";
|
||||
};
|
||||
|
||||
// be authoritative for the localhost forward and reverse zones, and for
|
||||
// broadcast zones as per RFC 1912
|
||||
|
||||
zone "localhost" {
|
||||
type master;
|
||||
file "/etc/bind/db.local";
|
||||
};
|
||||
|
||||
zone "127.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.127";
|
||||
};
|
||||
|
||||
zone "0.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.0";
|
||||
};
|
||||
|
||||
zone "255.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.255";
|
||||
};
|
||||
|
||||
|
38
AK/bind/named.conf.local
Normal file
38
AK/bind/named.conf.local
Normal file
@ -0,0 +1,38 @@
|
||||
//
|
||||
// Do any local configuration here
|
||||
//
|
||||
|
||||
// Consider adding the 1918 zones here, if they are not used in your
|
||||
// organization
|
||||
//include "/etc/bind/zones.rfc1918";
|
||||
|
||||
zone "ak.local" {
|
||||
type master;
|
||||
file "/etc/bind/db.ak.local";
|
||||
};
|
||||
|
||||
zone "ak.netz" {
|
||||
type master;
|
||||
file "/etc/bind/db.ak.netz";
|
||||
};
|
||||
|
||||
zone "0.168.192.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.192.168.0.0";
|
||||
};
|
||||
|
||||
zone "128.168.192.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.192.168.128.0";
|
||||
};
|
||||
|
||||
zone "0.16.172.in-addr.arpa" {
|
||||
type master;
|
||||
file "/etc/bind/db.172.16.0.0";
|
||||
};
|
||||
|
||||
|
||||
zone "k1371.dyndns.org" {
|
||||
type master;
|
||||
file "/etc/bind/db.k1371.dyndns.org";
|
||||
};
|
8
AK/bind/named.conf.local.ORIG
Normal file
8
AK/bind/named.conf.local.ORIG
Normal file
@ -0,0 +1,8 @@
|
||||
//
|
||||
// Do any local configuration here
|
||||
//
|
||||
|
||||
// Consider adding the 1918 zones here, if they are not used in your
|
||||
// organization
|
||||
//include "/etc/bind/zones.rfc1918";
|
||||
|
110
AK/bind/named.conf.options
Normal file
110
AK/bind/named.conf.options
Normal file
@ -0,0 +1,110 @@
|
||||
options {
|
||||
directory "/var/cache/bind";
|
||||
|
||||
// If there is a firewall between you and nameservers you want
|
||||
// to talk to, you may need to fix the firewall to allow multiple
|
||||
// ports to talk. See http://www.kb.cert.org/vuls/id/800113
|
||||
|
||||
// If your ISP provided one or more IP addresses for stable
|
||||
// nameservers, you probably want to use them as forwarders.
|
||||
// Uncomment the following block, and insert the addresses replacing
|
||||
// the all-0's placeholder.
|
||||
|
||||
// forwarders {
|
||||
// 0.0.0.0;
|
||||
// };
|
||||
|
||||
/*
|
||||
forwarders {
|
||||
// OpenDNS servers
|
||||
208.67.222.222;
|
||||
208.67.220.220;
|
||||
// DNS-Cache des CCC
|
||||
213.73.91.35;
|
||||
// ISP DNS Servers
|
||||
217.0.43.193;
|
||||
194.25.2.129;
|
||||
};
|
||||
*/
|
||||
|
||||
|
||||
// Security options
|
||||
listen-on port 53 {
|
||||
127.0.0.1;
|
||||
192.168.0.254;
|
||||
172.16.0.1;
|
||||
};
|
||||
allow-query {
|
||||
127.0.0.1;
|
||||
192.168.0.0/16;
|
||||
172.16.0.0/16;
|
||||
10.0.0.0/8;
|
||||
#fe80::/8;
|
||||
#::1/128;
|
||||
};
|
||||
allow-recursion {
|
||||
127.0.0.1;
|
||||
192.168.0.0/16;
|
||||
172.16.0.0/16;
|
||||
10.0.0.0/16;
|
||||
#fe80::/8;
|
||||
#::1/128;
|
||||
};
|
||||
allow-transfer { none; };
|
||||
|
||||
auth-nxdomain no; # conform to RFC1035
|
||||
|
||||
// turns off IPv6
|
||||
listen-on-v6 { none; };
|
||||
|
||||
// turns on IPv6 for port 53
|
||||
/*
|
||||
listen-on-v6 {
|
||||
::1;
|
||||
};
|
||||
*/
|
||||
|
||||
};
|
||||
|
||||
logging {
|
||||
channel simple_log {
|
||||
file "/var/log/named/bind.log" versions 3 size 5m;
|
||||
severity warning;
|
||||
print-time yes;
|
||||
print-severity yes;
|
||||
print-category yes;
|
||||
};
|
||||
channel queries_log {
|
||||
file "/var/log/named/query.log" versions 5 size 2m;
|
||||
severity info;
|
||||
print-time yes;
|
||||
print-severity yes;
|
||||
print-category no;
|
||||
};
|
||||
channel log_zone_transfers {
|
||||
file "/var/log/named/axfr.log" versions 3 size 2m;
|
||||
//severity info;
|
||||
severity debug 4;
|
||||
print-time yes;
|
||||
print-severity yes;
|
||||
print-category yes;
|
||||
};
|
||||
category resolver {
|
||||
queries_log;
|
||||
};
|
||||
category queries {
|
||||
queries_log;
|
||||
};
|
||||
category xfer-in {
|
||||
log_zone_transfers;
|
||||
};
|
||||
category xfer-out {
|
||||
log_zone_transfers;
|
||||
};
|
||||
category notify {
|
||||
log_zone_transfers;
|
||||
};
|
||||
category default{
|
||||
simple_log;
|
||||
};
|
||||
};
|
26
AK/bind/named.conf.options.ORIG
Normal file
26
AK/bind/named.conf.options.ORIG
Normal file
@ -0,0 +1,26 @@
|
||||
options {
|
||||
directory "/var/cache/bind";
|
||||
|
||||
// If there is a firewall between you and nameservers you want
|
||||
// to talk to, you may need to fix the firewall to allow multiple
|
||||
// ports to talk. See http://www.kb.cert.org/vuls/id/800113
|
||||
|
||||
// If your ISP provided one or more IP addresses for stable
|
||||
// nameservers, you probably want to use them as forwarders.
|
||||
// Uncomment the following block, and insert the addresses replacing
|
||||
// the all-0's placeholder.
|
||||
|
||||
// forwarders {
|
||||
// 0.0.0.0;
|
||||
// };
|
||||
|
||||
//========================================================================
|
||||
// If BIND logs error messages about the root key being expired,
|
||||
// you will need to update your keys. See https://www.isc.org/bind-keys
|
||||
//========================================================================
|
||||
dnssec-validation auto;
|
||||
|
||||
auth-nxdomain no; # conform to RFC1035
|
||||
listen-on-v6 { any; };
|
||||
};
|
||||
|
4
AK/bind/rndc.key
Normal file
4
AK/bind/rndc.key
Normal file
@ -0,0 +1,4 @@
|
||||
key "rndc-key" {
|
||||
algorithm hmac-md5;
|
||||
secret "ckecWIFiA+MZIA/mQdCjxQ==";
|
||||
};
|
20
AK/bind/zones.rfc1918
Normal file
20
AK/bind/zones.rfc1918
Normal file
@ -0,0 +1,20 @@
|
||||
zone "10.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
|
||||
zone "16.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "17.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "18.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "19.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "20.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "21.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "22.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "23.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "24.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "25.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "26.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "27.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "28.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "29.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "30.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
zone "31.172.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
||||
|
||||
zone "168.192.in-addr.arpa" { type master; file "/etc/bind/db.empty"; };
|
40
AK/cron_root.AK
Normal file
40
AK/cron_root.AK
Normal file
@ -0,0 +1,40 @@
|
||||
# DO NOT EDIT THIS FILE - edit the master and reinstall.
|
||||
# (/tmp/crontab.WePILJ/crontab installed on Wed Feb 28 14:42:06 2018)
|
||||
# (Cron version -- $Id: crontab.c,v 2.13 1994/01/17 03:20:37 vixie Exp $)
|
||||
# Edit this file to introduce tasks to be run by cron.
|
||||
#
|
||||
# Each task to run has to be defined through a single line
|
||||
# indicating with different fields when the task will be run
|
||||
# and what command to run for the task
|
||||
#
|
||||
# To define the time you can provide concrete values for
|
||||
# minute (m), hour (h), day of month (dom), month (mon),
|
||||
# and day of week (dow) or use '*' in these fields (for 'any').#
|
||||
# Notice that tasks will be started based on the cron's system
|
||||
# daemon's notion of time and timezones.
|
||||
#
|
||||
# Output of the crontab jobs (including errors) is sent through
|
||||
# email to the user the crontab file belongs to (unless redirected).
|
||||
#
|
||||
# For example, you can run a backup of all your user accounts
|
||||
# at 5 a.m every week with:
|
||||
# 0 5 * * 1 tar -zcf /var/backups/home.tgz /home/
|
||||
#
|
||||
# For more information see the manual pages of crontab(5) and cron(8)
|
||||
#
|
||||
# m h dom mon dow command
|
||||
PATH=/root/bin:/usr/local/sbin:/usr/local/bin:/usr/sbin:/usr/bin:/sbin:/bin
|
||||
|
||||
# - Check if postfix mailservice is running. Restart service if needed.
|
||||
# -
|
||||
*/10 * * * * /root/bin/monitoring/check_postfix.sh
|
||||
|
||||
# - Copy gateway configuration
|
||||
# -
|
||||
09 4 * * * /root/bin/manage-gw-config/copy_gateway-config.sh AK
|
||||
|
||||
|
||||
# - Poweroff machine at 2018-03-07 11:50h
|
||||
# -
|
||||
55 11 * * * /root/bin/admin-stuff/machine_poweroff.sh 2018-03-07
|
||||
|
Some files were not shown because too many files have changed in this diff Show More
Reference in New Issue
Block a user